Screw and bolt size charts for OEM buyers: how to read diameter, pitch, and length before you RFQ
A size chart only helps an OEM desk when each column maps to a named RFQ field. This guide shows how to read diameter, pitch or TPI, length measurement convention, head type, and drive off a chart—then put those locks on one brief—before you compare quotes. It is not a rewrite of how to measure screw length or single-spec notes such as M4 × 0.7 screw meaning; those pages cover measurement or one designation. Catalogue photos in the stainless steel screws category or bolts category also do not replace named size fields on the enquiry.
Ruike (Ningbo Hongyuan Precision Hardware Manufacturing Co., Ltd. / HY) supports OEM dimensional verification after quote. Plant footprint and capacity live on About Ruike — not repeated here. Dimensional checks do not replace locking size fields on the RFQ.
Define: size chart as RFQ field map
Worked example: the buyer needs an M8 × 1.25 × 30 hex-head part (metric coarse; length = 30 mm under head) and may also hold an inch line such as 5/16-18 × 1-1/4 UNC. A size chart is useful only if the desk maps columns to nominal diameter, pitch / TPI, length measurement convention, head type, and drive—then attaches the drawing when geometry is controlled.
Property class or stainless grade is not a size-chart column substitute. Call A2-70, 8.8, or the buyer print as separate RFQ lines—see the fastener strength guide for strength language, not for diameter.
Field table — worked example: M8 × 1.25 × 30 (hex head) + optional inch twin
Cluster-unique locks for this Size Charts pillar. Generic enquiry cells (qty / MOQ / lead / certificates / full cross-family checklist) are covered by the unified RFQ block before Agree — do not duplicate those rows here.
Numeric across-flats / head-height cells: 待补证据 until an ISO/ASME/DIN excerpt is linked.
| Chart / RFQ field | Example lock (M8×1.25×30) | Why wrong reading breaks quote or fit |
|---|---|---|
| Nominal diameter | M8 (not “≈8 mm” alone) | Hole / nut / clearance wrong |
| Pitch / thread series | 1.25 metric coarse (state fine if M8×1) | Mating thread mismatch |
| Length L + method | 30 mm under head for hex head | Countersunk overall-length mix-up shortens clamp |
| Head type | Hexagon head | Drive / wrench / seat stack change |
| Drive / wrenching | External hex; across-flats s — 待补证据 for table value | Socket / spanner clearance |
| Thread length b | Full vs partial — standard callout | Grip vs engagement (→ hex bolts OEM selection guide) |
| Inch twin (if dual stock) | 5/16-18 UNC × 1-1/4 — not auto-equal to M8×30 | Metric↔inch needs explicit system |
| Grade / material | A2-70 or buyer print — separate from size columns | Strength / corrosion ≠ diameter |
| Tolerance class | e.g. 6g if drawing-controlled | Gauge acceptance |
Discuss: size-chart failure modes that break the quote
1. Read chart columns before copying a row
Diameter without pitch is incomplete. Length without measurement method is incomplete. Confirm pitch with how to measure screw thread pitch when the chart row is ambiguous.
2. Worked metric row — M8×1.25×30 hex
Map each cell in the table above to one RFQ line. Treat “M8×30” as unfinished until pitch and length method are written.
3. Scenario A — “M8×30” with no pitch
Supplier desks often assume metric coarse 1.25. Fine-thread assemblies then fail at the nut or tap. Return a clarifying pitch before treating the quote as firm.
4. Scenario B — inch twin vs metric near-size
5/16-18 × 1-1/4 UNC is not a drop-in for M8 × 1.25 × 30. State both systems explicitly. Until a dedicated metric-vs-imperial guide is live, use the near-term metric vs inch machine screw cross-reference for dual-system RFQ hygiene—do not invent interchangeability.
5. Scenario C — countersunk length taken from a hex chart
Hex-head length on charts is typically under-head; countersunk families often use overall length. Mixing conventions shortens clamp or leaves a proud head. Keep length method on the RFQ and follow how to measure screw length.
6. Scenario D — partial chart without CAD
Discovery quotes can proceed if diameter, pitch/TPI, length method, material family, and head/drive are listed. Production still needs a drawing or approved sample—route non-standard geometry through the customized screw path. Do not invent MOQ or lead time from a chart cell.
Plant / QC capacity: see About Ruike.
Decision table
| Need | Lock on RFQ from chart? | Enough alone? | Notes |
|---|---|---|---|
| Fit mating nut / tap | Dia + pitch / TPI | + tolerance if critical | Pitch-measure article |
| Clamp / stack height | Length + method + head height if envelope-critical | Head family matters | Length-measure article |
| Tool access | Across-flats / drive | Separate from strength | Head/drive on brief |
| Dual metric–inch sourcing | Both designations spelled out | Never “approx. equal” only | Metric/inch cross-ref |
| Strength / corrosion | Grade / material / finish | Not a size-chart cell | Strength guide |
| Custom / non-std | Drawing Rev + dims | Chart is reference only | Customized-screw category |
Length method before RFQ. Chart rows that show a length number still need the measurement convention locked—under-head vs overall—especially when the same nominal size appears on hex and countersunk families. Confirm the method with how to measure screw length, put diameter × pitch/TPI × length-method on one brief, then send the enquiry via Get a Quote. Do not invent across-flats or head-height cells without a linked standard excerpt (待补证据).
RFQ checklist: fields to lock before you compare quotes
Use this checklist on every Ruike OEM enquiry so quotes stay same-scope. Leave a cell blank only when the drawing truly does not apply — do not invent values.
| RFQ field | What to lock (examples) | Notes |
|---|---|---|
| Thread system | Metric or inch (UNC/UNF) — one system per joint | Dual-source BOMs: spell both designations; never “≈ mm” only |
| Nominal size | Diameter × pitch (mm) or major dia × TPI | e.g. M8 × 1.25 or 5/16-18 |
| Length + method | Length value + under-head vs overall | Countersink families often use overall — state the method |
| Head / drive | Head style + drive type | External hex ≠ hex socket; button ≠ socket-cap |
| Thread length family | Full vs partial (buyer-named standard) | e.g. DIN 933 / ISO 4017 full vs DIN 931 / ISO 4014 partial — clause text 待补证据 |
| Material / alloy / grade | Carbon property class or stainless alloy family | e.g. 8.8 / Grade 5 / A2-70 / 304 vs 316 — do not RFQ bare “SS” or “grade” alone |
| Finish / passivation | Coating or passivation need | Galling / anti-seize note when stainless-on-stainless |
| Drawing / Rev / sample | PDF/CAD Rev or approved sample | Required for production; discovery may start from named fields |
| Mating hardware | Nuts / washers in or out of scope | Keep nut grade/alloy aligned with bolt when required |
| Qty / MOQ | Target qty; MOQ if known | pending — do not invent MOQ from a catalogue cell |
| Target lead time / ship-to | Window + Incoterms if known | pending — plant calendar not published here |
| Certificates | Buyer-named scopes (e.g. RoHS / REACH) | Cite only granted scopes; do not claim IATF or other marks unless currently listed (待补证据) |
When the checklist cells that change fit and strength are filled, submit the brief via Get a Quote. Attach the drawing or sample photo on the same enquiry. For non-catalog geometry, use the customized screw path after the material and head/drive locks above.
Agree: lock the chart fields, then quote
Lock diameter × pitch/TPI × length-method (+ head/drive) — example M8 × 1.25 × 30 under-head hex — then submit at Get a Quote. Sisters: how to measure screw length, hex bolts OEM selection, metric vs imperial fasteners.
QC / dimensional-check photograph from Ningbo Ruike Precision Hardware (HY) plant imagery. Ruike Fasteners (Ningbo Hongyuan Precision Hardware Manufacturing Co., Ltd.) — OEM enquiry via hy-fastener.com.
FAQ
What dimensions belong on an OEM size chart before we send a drawing?
Call out nominal diameter, thread pitch (or TPI), length measurement convention, head type, and drive — then attach the drawing. Specific numeric chart cells (across-flats, head height formulas): 待补证据.
How do metric and inch size charts differ on an RFQ?
Metric uses mm + pitch; inch uses major diameter + TPI (UNC/UNF). State the system explicitly so suppliers do not dual-interpret. Use the metric vs inch machine screw cross-reference until a broader metric-vs-imperial guide is live.
Can we RFQ from a partial chart without a full CAD model?
Yes for discovery quotes if diameter, pitch/TPI, length, material family, and head/drive are listed; final production still needs a drawing or approved sample. No invented MOQ or lead time.