Role: This page is the measurement action note—how to take length from a sample (under-head vs overall) so the RFQ does not mix methods. It is not the OEM size-chart / designation reading guide. After the method is locked, read chart rows and enquiry fields on screw & bolt size charts OEM buyer guide, then submit Get a Quote. Confirm width across flats and head height against the applicable product standard and approved drawing.
A screw can have the correct thread and still be the wrong length for an assembly. One buyer may report overall length while another reports length below the head. The difference becomes expensive when the screw bottoms in a blind hole, protrudes into a moving part or leaves too little usable thread.
This guide explains the measurement reference first, then shows how to turn a physical sample into an unambiguous OEM order. It covers screws for engineered assemblies; photographs illustrate product form and do not establish dimensions or tolerances.
1. Find the head’s seating reference before measuring

| Head or part form | Usual length reference | What to confirm |
|---|---|---|
| Pan, socket cap, truss or another raised head | Underside bearing face to the end | Separate head height from nominal screw length. |
| Flat countersunk | Top of the head to the end | Confirm countersink geometry as well as length. |
| Raised countersunk / oval | Widest head plane to the end; dome excluded | Check the product standard or dimensioned drawing. |
| Shoulder screw | Use the drawing’s shoulder and thread dimensions | Do not replace shoulder length with total length below the head. |
| Set screw / headless part | Usually end to end | Confirm point form and the defined dimension. |
The label “countersunk” alone is insufficient when a raised dome is present. Confirm the length reference against the specified product drawing or applicable product standard.


2. Measure a physical sample in a repeatable way
- Identify the screw form. Record whether the head is raised, flat countersunk, raised countersunk or a special design. A side-view photograph is useful, but a dimensioned drawing is better.
- Select a suitable tool. A ruler can screen a nominal length; use a suitable calibrated measuring instrument when checking a specified tolerance. Choose resolution and accuracy for the acceptance requirement.
- Check the measurement faces. Remove loose debris. A burr, damaged tip or plating buildup can change the reading. Do not grind a production part simply to obtain a favorable measurement.
- Align the part with the measuring axis. Seat the jaw against the defined head reference and the other jaw against the specified end. Avoid diagonal contact or measuring from the curved top of a raised head.
- Record the result with its definition. Write the unit, reference points, tool and drawing revision beside the reading. “Length checked” is not a usable inspection record.
When a tip is rounded, pointed or specially formed, its geometry also belongs in the specification. Two screws that share a nominal length may behave differently at the bottom of a blind hole.
OEM RFQ module — lock these fields before you compare quotes
A correct length number still needs the measurement convention on the same brief. Use the checklist so supplier and buyer share one method.
Cover all seven information classes below. Leave a cell blank only when the drawing truly does not apply — do not invent MOQ, lead time, or salt-spray hours.
| RFQ field | What to lock | Notes |
|---|---|---|
| Material / alloy | Material / alloy if known from sample or BOM; else state “sample only—confirm alloy”. | Required for same-scope quotes |
| Grade / property class | Class/grade if marked on sample head; do not guess from appearance alone. | Named family; no hybrids |
| Tolerance or head/drive | Head style observed + drive type; countersink families often use overall length—state method. | Page-theme cell |
| Usable thread / length method | Length value + under-head vs overall (required). Usable thread length if partial-thread joint. | Avoid method mix-ups |
| Quantity | Target qty for this SKU / release; MOQ only if buyer already knows (buyer-filled — do not invent) | Pending plant MOQ cells |
| Destination port / ship-to | Ship-to city/port + Incoterms if known (buyer-filled) | Lead time calendar not published here |
| Drawing / Rev / sample | PDF/CAD Rev or approved sample photo on the same enquiry | Required for production RFQ |
When the cells that change fit and strength are filled, submit via Get a Quote and attach the drawing or sample on the same enquiry. Prefer a written desk path? Use Contact Us.
Related OEM next steps:
- Send drawings for length and thread check
- Screw & bolt size charts for OEM buyers
- Thread engagement vs grip length on RFQ drawings
3. Read M4 × 0.7 × 20 without mixing the dimensions
In a metric screw designation written as M4 × 0.7 × 20, M4 identifies a nominal 4 mm thread diameter, 0.7 identifies a 0.7 mm pitch and 20 identifies the nominal length in millimeters. The head type determines where that last dimension starts. It does not mean a measured thread crest must read exactly 4.000 mm, and it does not tell you the head height or the threaded length.
| Term | Meaning | Common mistake |
|---|---|---|
| Nominal screw length | The designated length using the head’s reference | Including a raised head in a below-head dimension. |
| Overall length | Physical end-to-end envelope | Ordering a raised-head part from its overall measurement. |
| Threaded length | Axial extent of the specified threaded portion | Assuming every nominally 20 mm screw is fully threaded. |
| Usable engagement | Thread engagement that can actually carry the joint’s load | Counting a tip, runout or incomplete thread as full engagement. |

4. Check the length against the assembly, not just the sample
For a raised-head screw, a useful preliminary geometry check is:
Nominal length below the head ≈ clamped stack + required insertion depth
Illustrative example: a 3 mm bracket, 2 mm spacer and 1 mm washer create a 6 mm stack. If an engineer specifies 8 mm insertion beyond that stack, the preliminary geometric length is 14 mm. This calculation is not a strength calculation or a recommendation that 8 mm is enough engagement. Available sizes, stack tolerances, entry chamfers, incomplete threads and bottom clearance still need review.
For a blind tapped hole, confirm the usable threaded depth rather than just the drilled depth. For a countersunk joint, use the drawing’s seating plane; do not automatically add the full head height to a stack calculation. A shoulder screw needs its own shoulder fit and thread engagement check.

5. Send a measurement record that a supplier can quote
An annotated drawing prevents repeated questions. When only a sample is available, include side and top views, a thread identification and a record like this:
| Field | Illustrative request — not a Hongyuan test result |
|---|---|
| Part identification | Raised-head hex-socket machine screw; internal part number and drawing revision. |
| Thread | M4 × 0.7; required thread tolerance specified on drawing. |
| Length definition | 20 mm nominal, underside bearing face to end. |
| Acceptance limits | Enter the actual drawing limits; do not assume a general tolerance. |
| Other dimensions | Head diameter/height, threaded length, tip form and clearance restrictions. |
| Commercial inputs | Material, finish, quantity, packaging and intended application. |
From measured length to RFQ chart fields. A correct length number still needs the measurement convention on the same brief—under-head vs overall—especially when the same nominal size appears on hex and countersunk families. Confirm the method with the steps on this page, then carry diameter × pitch/TPI × length-method into screw & bolt size charts OEM buyer guide so chart rows and the enquiry use one convention. Submit via Get a Quote. Obtain the required head dimensions from the specified product standard or approved drawing.
Frequently asked questions
Do I include the head when measuring screw length?
Include the head for a flat countersunk screw. Exclude a raised bearing head. A raised countersunk head normally excludes the dome above its seating reference, so use the relevant drawing or standard.
Can I identify pitch by measuring the screw’s length?
No. Pitch describes the axial spacing of adjacent threads. Use an appropriate thread gauge or another suitable identification method; length and pitch answer different questions.
Does a longer screw make a stronger joint?
Not automatically. A longer part can bottom out or interfere with adjacent components. Material, joint design, usable engagement and installation conditions govern the joint.
Can Hongyuan quote from a sample?
Send the sample information and application requirements for review. Any dimensions that remain uncertain should be resolved through the agreed drawing and sample approval before production.
Agree: lock length-method, then read the chart into the quote
State length value + under-head vs overall on every sample-based enquiry. Use screw & bolt size charts OEM buyer guide for designation / chart reading, then Get a Quote. Sisters: hex bolts OEM selection, M4 × 0.7 meaning (single-size satellite).
OEM buyer decisions — before you RFQ
Why does under-head vs overall matter on the RFQ?
The same nominal size can appear on hex and countersunk families with different length conventions. A number without the method produces wrong blanks and wrong quotes. Lock length value + under-head vs overall on every sample-based enquiry.
We measured a sample—what else must go on the brief?
Diameter × pitch or TPI, head style + drive observed, material/grade if marked or known, full vs partial thread if relevant, quantity, ship-to if known, and a photo of the measurement setup or the sample next to a scale. Then send Get a Quote with those locks.
Can we skip the method if we send a 3D model?
Still state the contractual length method the print uses. Models help, but buyers and plants must agree which datum defines “length” on the order. Put the print Rev and the method in the same message.
Is this page a substitute for an OEM size chart?
No. This page is the measurement action note. Chart reading / designation rows belong on the size-charts OEM buyer guide after the method is locked. Do not invent across-flats or head-height cells without a linked standard excerpt.
Where do measured lengths get quoted?
After method + geometry cells are filled, use Get a Quote. Contact Us is available for desk questions; do not expect a binding production quote from length alone without material/grade and drawing scope.
Ready to lock the fields above? Submit a drawing-based brief via Get a Quote.
Next step — drawing-based OEM enquiry
Method locked—carry diameter × pitch/TPI × length-method into the quote form.
- Get a Quote — preferred RFQ form for drawings / Rev / sample photos (production path).
- Contact Us — desk path for clarification before the formal RFQ.
Do not send bare “high strength / SS / standard screw” labels without the seven-field locks above. Hongyuan quotes from buyer-named fields + drawing scope — not from catalogue guesswork.